OMNIBUS
I/O Modules > AD40

| Feartures |
Applications |
·
2 - 12 Bit, 40 MHz Independent A/D Channels
· Large FIFO Available for Transient
Capture
· Programmable Analog Level Trigger-
Pre/Post Buffering |
·
Wireless
· High-Energy Physics
· Transient Capture
|
|
Overview
The AD40 module features two, independent, very-high-speed
analog input channels making it ideal for high-speed
data acquisition and transient capture systems. Each
channel employs Analog Devices AD9224 monolithic,
single supply 12-bit, 40 MSPS analog to digital converter
with an on-chip, high performance sample-and-hold amplifier
and voltage reference. The A/D uses a multistage differential
pipelined architecture with output error correction
logic to provide 12-bit accuracy at up to 40 MHz data
rates, and guarantees no missing codes over the full
operating temperature range. A single clock input is
used to control all internal conversion cycles. An out-of-range
signal indicates an overflow condition which can be
used with the most significant bit to determine low
or high overflow. On-board circuitry adds gain/offset
error adjustments for each channel to insure accurate
measurements.
|